20 LBS Powder Fire Extinguisher(usa Module)

20 LBS Powder Fire Extinguisher(usa Module)

Certification: UL / FM / ULC (market entry approval)
Fire Rating: A / B / C (10A–120B range)
Capacity: 8.5–30 lb (3.7–13.6 kg)
Discharge Performance: 11–27 sec / 17–30 ft range
Agent Type: PLUS-FIFTY C / FORAY / Purple-K
Operating Range: down to -54°C (optional low-temp version)
Share to
Send Inquiry
Description
Technical Parameters

Shaoxing Weimin Fire Fighting Equipment Co., Ltd. is one of the most reliable manufacturers and suppliers of 20 lbs powder fire extinguisher(usa module) in China. If you're going to wholesale bulk CE and ISO approved 20 lbs powder fire extinguisher(usa module), welcome to get pricelist and free sample from our factory. All customized products are with high quality and low price.

 

Product Architecture Overview

The 20 LBS dry chemical fire extinguisher (USA module) is a 9 kg ABC powder pressurized discharge device built around a steel pressure cylinder + nitrogen gas propulsion system, designed for US-style installation layouts.

The structure consists of:

  • cylindrical steel shell (carbon steel pressure vessel)
  • internal powder storage chamber filled with ABC dry chemical agent
  • dip tube connecting powder reservoir to valve outlet
  • brass manual valve assembly for mechanical opening and sealing
  • nitrogen pressurization chamber maintaining 195–240 PSI working pressure range
The system is designed to store solid powder under gas pressure and release it through mechanical valve opening without external energy input.

Technical Specifications 

Model I-10-G I-A-10-G I-K-10-G I-20-G I-A-20-G I-K-20-G I-30-G I-A-30-G I-K-30-G
Agent PLUS-FIFTY C FORAY Purple-K PLUS-FIFTY C FORAY Purple-K PLUS-FIFTY C FORAY Purple-K
Capacity 10 lb (4.5 kg) 8.5 lb (3.7 kg) 9 lb (4.1 kg) 20 lb (9.1 kg) 17 lb (7.7 kg) 18 lb (8.2 kg) 30 lb (13.6 kg) 25 lb (11.3 kg) 27 lb (12.3 kg)
UL Rating (USA) 30-B:C 4-A:40-B:C 60-B:C 40-B:C 10-A:60-B:C 80-B:C 60-B:C 20-A:80-B:C 120-B:C
ULC Rating (Canada) 30-B:C 3-A:40-B:C 60-B:C 40-B:C 10-A:80-B:C 80-B:C 40-B:C 10-A:80-B:C 120-B:C
US Coast Guard Classification Type B:C, Size II

Type A, Size II

 

Type B:C, Size II

Type B:C, Size II Type B:C, Size III

Type A, Size II

 

Type B:C, Size II

Type B:C, Size III Type B:C, Size IV

Type A, Size II

 

Type B:C, Size III

Type B:C, Size IV
Discharge Time 11 seconds 15 seconds 19 seconds 13 seconds 20 seconds 21 seconds 17 seconds 25 seconds 27 seconds
Flow Rate 0.86 lb/s (0.39 kg/s) 0.63 lb/s (0.29 kg/s) 0.51 lb/s (0.23 kg/s) 1.34 lb/s (0.61 kg/s) 0.91 lb/s (0.41 kg/s) 0.90 lb/s (0.41 kg/s) 1.77 lb/s (0.80 kg/s) 1.02 lb/s (0.46 kg/s) 1.03 lb/s (0.47 kg/s)
Effective Range 21 ft (6.4 m) 17 ft (5.2 m) 25 ft (7.6 m) 24 ft (7.3 m) 20 ft (6.1 m) 30 ft (9.1 m) 23 ft (7.0 m) 20 ft (6.1 m) 30 ft (9.1 m)
Nozzle Jet Type Conical Conical Conical Conical Conical Conical Conical Conical Conical
Optional Features
• Low temperature (down to -65°F / -54°C) N/A X N/A N/A X X N/A X X
• Corrosion resistant N/A X X X X X X X X
• Needle valve X X X X X X X X X
• High flow rate N/A N/A N/A N/A X X N/A X X
Optional Flow Rate - - - - 1.55 lb/s (0.70 kg/s) 1.55 lb/s (0.70 kg/s) - 2.10 lb/s (0.95 kg/s) 2.35 lb/s (1.10 kg/s)
Optional Effective Discharge Time - - - - 12 seconds 12 seconds - 12 seconds 12 seconds
Optional Effective Range - - - - 15–20 ft (4.6–6.1 m) 15–20 ft (4.6–6.1 m) - 15–20 ft (4.6–6.1 m) 15–20 ft (4.6–6.1 m)
Optional Classification - - - - 1-A:20-B:C 20-B:C - 1-A:20-B:C 20-B:C
Certifications UL, FM, USCG** UL, FM, USCG** UL, FM, USCG** UL, FM, USCG** UL, FM, USCG** UL, FM, USCG** UL, FM, USCG** UL, FM, USCG** UL, FM, USCG**
Mounting Brackets                  
• Universal bracket*** 14228 14228 14228 14091 14091 14091 14098 14098 14098
• High resistance bracket*** 30886 30886 30886 3075 30759 30759 30889 30889 30889
• High resistance ring pass-through bracket N/A N/A N/A 15665 15665 15665 25428 25428 25428
Full Charged Weight 22 lb (10.0 kg) 20.5 lb (9.3 kg) 21 lb (9.5 kg) 38 lb (17.2 kg) 35 lb (15.9 kg) 36 lb (16.3 kg) 54.5 lb (24.7 kg) 49.5 lb (22.5 kg) 51.5 lb (23.4 kg)
Dimensions
Height 16.1" (40.9 cm) 16.1" (40.9 cm) 16.1" (40.9 cm) 20.5" (52.1 cm) 20.5" (52.1 cm) 20.5" (52.1 cm) 22.5" (57.2 cm) 22.5" (57.2 cm) 22.5" (57.2 cm)
Width 8.3" (20.9 cm) 8.3" (20.9 cm) 8.3" (20.9 cm) 10.4" (26.4 cm) 10.4" (26.4 cm) 10.4" (26.4 cm) 11.1" (28.3 cm) 11.1" (28.3 cm) 11.1" (28.3 cm)
Depth 5.3" (13.3 cm) 5.3" (13.3 cm) 5.3" (13.3 cm) 7.0" (17.8 cm) 7.0" (17.8 cm) 7.0" (17.8 cm) 8.0" (20.3 cm) 8.0" (20.3 cm) 8.0" (20.3 cm)
Hose Inner Diameter 0.4" (0.9 cm) 0.4" (0.9 cm) 0.4" (0.9 cm) 0.5" (3 cm) 0.5" (1.3 cm) 0.5" (1.3 cm) 0.6" (1.6 cm) 0.6" (1.6 cm) 0.6" (1.6 cm)
Hose Length 26.6" (67.6 cm) 26.6" (67.6 cm) 26.6" (67.6 cm) 31.6" (80.3 cm) 31.6" (80.3 cm) 31.6" (80.3 cm) 35.6" (90.5 cm) 35.6" (90.5 cm) 35.6" (90.5 cm)
Cylinder Outer Diameter 4.9" (12.4 cm) 4.9" (12.4 cm) 4.9" (12.4 cm) 6.0" (15 cm) 6.0" (15 cm) 6.0" (15 cm) 7.0" (17.5 cm) 7.0" (17.5 cm) 7.0" (17.5 cm)
Fire Suppression Coverage*
Novice Operator Coverage 30 ft² (2.8 m²) 40 ft² (3.7 m²) 60 ft² (5.6 m²) 40 ft² (3.7 m²) 60 ft² (5.6 m²) 80 ft² (7.4 m²) 60 ft² (5.6 m²) 80 ft² (7.4 m²) 120 ft² (11.1 m²)
Experienced Operator Coverage 75 ft² (6.9 m²) 100 ft² (9.3 m²) 150 ft² (13.9 m²) 100 ft² (9.3 m²) 150 ft² (13.9 m²) 200 ft² (18.6 m²) 150 ft² (13.9 m²) 200 ft² (18.6 m²) 300 ft² (27.9 m²)

 

Working Mechanism

When the valve lever is pressed, the sealing interface is mechanically opened and nitrogen gas begins to expand inside the cylinder.

The process follows three controlled steps:

  1. nitrogen pressure acts on powder bed and pushes solid particles into dip tube inlet
  2. powder is transferred through internal channel and valve body under gas-driven flow
  3. nozzle converts pressure energy into directional particle stream toward combustion zone

During discharge, the system maintains continuous powder flow for a controlled time window under 195–240 PSI pressure decay behavior, depending on temperature and valve resistance.

👉 The mechanism does not cool the fire; it interrupts combustion by physically covering and isolating oxygen contact surfaces.

20 LBS powder fire extinguisher(usa module

Material & Component System 

Cylinder body

material: carbon steel sheet with welded or seamless forming (configuration dependent)

function: resist internal gas pressure and maintain structural integrity under cyclic load

pressure test: hydrostatic verification typically above 3× working pressure level

Powder agent

composition: ABC dry chemical powder (ammonium phosphate based)

particle function: forms insulating layer on burning surface and blocks oxygen diffusion channels

storage condition: sealed internal environment to reduce moisture-induced agglomeration

Valve system

details: brass alloy valve body with manual lever structure

sealing: interface uses elastomer O-ring to reduce nitrogen leakage under static storage pressure

dip tube: rigid polymer or metal tube conducts powder from bottom reservoir

Each component is designed to transfer pressure energy into solid particle motion without phase conversion.

Fire Application Conditions

The 20 LBS configuration is selected for medium fire load density zones where localized suppression is required within 10–12 m distance range.

Class A solid combustion zones

Materials: stacked wood pallets, cardboard cartons, textile storage

Condition: surface combustion with oxygen diffusion

Action: powder deposits on surface and interrupts oxidation reaction pathway

Class B liquid fuel zones

Materials: gasoline, diesel, industrial lubricants

Condition: vapor combustion above liquid surface

Action: powder disperses flame layer and reduces vapor ignition continuity

Class C electrical zones

Condition: energized equipment (low to medium voltage industrial systems)

Requirement: non-conductive discharge behavior under gas-powder system

Action: powder separates flame path without electrical conduction

Pressure System Behavior

The extinguisher operates under nitrogen-driven pressure range of 195–240 PSI, which varies with ambient temperature between -30°C to +60°C operating window.

Key pressure behaviors:

  • temperature drop: gas contraction reduces discharge range
  • temperature rise: internal pressure increases and accelerates powder flow
  • seal degradation: micro-leakage reduces stored energy capacity

The system uses hydrostatic validation and seal compression control to maintain pressure retention during storage and transport cycles.

Installation & Integration Method

The unit is installed as a mechanical fire response module in fixed positions:

  • wall bracket mounting using steel support frame
  • anchor bolts (M8 specification commonly used in industrial installation)
  • installation height typically aligned with manual access zone (0.8–1.2 m range)

Operational integration:

  • no electrical input required
  • no pipeline connection required
  • activation performed by manual lever displacement that opens valve sealing path

The system is designed to convert static storage pressure into immediate discharge response without auxiliary systems.

Failure Modes & Engineering Risk Control

Identified failure mechanisms:

  • valve seal fatigue nitrogen leakage reduces internal pressure below operational threshold
  • powder moisture absorption increases internal friction and blocks dip tube flow
  • nozzle restriction reduces particle velocity and effective discharge distance
  • cylinder corrosion localized wall thinning under long-term humidity exposure

Control methods applied in production:

  • controlled humidity filling environment during powder loading
  • torque-controlled valve assembly to maintain seal compression force
  • batch sampling discharge test to verify flow continuity and pressure retention

Manufacturing & Quality Traceability 

Weimin production process separates structural, filling, and pressure stages:

  1. cylinder forming and welding or seamless shaping
  2. hydrostatic pressure test to validate structural integrity
  3. internal surface treatment to reduce corrosion interaction
  4. ABC powder filling under controlled moisture conditions
  5. valve assembly with torque calibration
  6. nitrogen pressurization to 195–240 PSI target range
  7. final inspection including weight verification and batch traceability marking

Each unit is linked to a batch-level production record for export inspection tracking.

Procurement Interface 

For configuration and quotation, buyers typically define:

  • installation scenario: warehouse / commercial building / industrial system
  • fire risk type: solid combustible / liquid fuel / electrical exposure
  • compliance requirement: US market installation standard
  • order quantity: project sample / container shipment level

Weimin responds with:

Pressure and cylinder configuration sheet • Export compliance documentation set • OEM label and marking structure • Production-based FOB quotation

Request for Quotation 

👉 To configure a 20 LBS dry chemical fire extinguisher supply plan for US market projects, provide your installation scenario and compliance requirement.

Weimin will map cylinder pressure system, valve configuration, and powder specification into a production quotation package based on batch manufacturing capability.

Submit Your Inquiry to Weimin

Hot Tags: 20 lbs powder fire extinguisher(usa module), China 20 lbs powder fire extinguisher(usa module) manufacturers, suppliers, factory, 20 LBS ABC Fire Extinguisher, 20LBS Fire Extinguisher, 2KG ABC Fire Extinguisher, 2KG Dry Powder Fire Extinguisher, ABC 10LBS Fire Extinguisher, Dry Chemical Fire Extinguishers