Shaoxing Weimin Fire Fighting Equipment Co., Ltd. is one of the most reliable manufacturers and suppliers of 20 lbs powder fire extinguisher(usa module) in China. If you're going to wholesale bulk CE and ISO approved 20 lbs powder fire extinguisher(usa module), welcome to get pricelist and free sample from our factory. All customized products are with high quality and low price.
Product Architecture Overview
The 20 LBS dry chemical fire extinguisher (USA module) is a 9 kg ABC powder pressurized discharge device built around a steel pressure cylinder + nitrogen gas propulsion system, designed for US-style installation layouts.
The structure consists of:
- cylindrical steel shell (carbon steel pressure vessel)
- internal powder storage chamber filled with ABC dry chemical agent
- dip tube connecting powder reservoir to valve outlet
- brass manual valve assembly for mechanical opening and sealing
- nitrogen pressurization chamber maintaining 195–240 PSI working pressure range
Technical Specifications
| Model | I-10-G | I-A-10-G | I-K-10-G | I-20-G | I-A-20-G | I-K-20-G | I-30-G | I-A-30-G | I-K-30-G |
|---|---|---|---|---|---|---|---|---|---|
| Agent | PLUS-FIFTY C | FORAY | Purple-K | PLUS-FIFTY C | FORAY | Purple-K | PLUS-FIFTY C | FORAY | Purple-K |
| Capacity | 10 lb (4.5 kg) | 8.5 lb (3.7 kg) | 9 lb (4.1 kg) | 20 lb (9.1 kg) | 17 lb (7.7 kg) | 18 lb (8.2 kg) | 30 lb (13.6 kg) | 25 lb (11.3 kg) | 27 lb (12.3 kg) |
| UL Rating (USA) | 30-B:C | 4-A:40-B:C | 60-B:C | 40-B:C | 10-A:60-B:C | 80-B:C | 60-B:C | 20-A:80-B:C | 120-B:C |
| ULC Rating (Canada) | 30-B:C | 3-A:40-B:C | 60-B:C | 40-B:C | 10-A:80-B:C | 80-B:C | 40-B:C | 10-A:80-B:C | 120-B:C |
| US Coast Guard Classification | Type B:C, Size II |
Type A, Size II Type B:C, Size II |
Type B:C, Size II | Type B:C, Size III |
Type A, Size II Type B:C, Size II |
Type B:C, Size III | Type B:C, Size IV |
Type A, Size II Type B:C, Size III |
Type B:C, Size IV |
| Discharge Time | 11 seconds | 15 seconds | 19 seconds | 13 seconds | 20 seconds | 21 seconds | 17 seconds | 25 seconds | 27 seconds |
| Flow Rate | 0.86 lb/s (0.39 kg/s) | 0.63 lb/s (0.29 kg/s) | 0.51 lb/s (0.23 kg/s) | 1.34 lb/s (0.61 kg/s) | 0.91 lb/s (0.41 kg/s) | 0.90 lb/s (0.41 kg/s) | 1.77 lb/s (0.80 kg/s) | 1.02 lb/s (0.46 kg/s) | 1.03 lb/s (0.47 kg/s) |
| Effective Range | 21 ft (6.4 m) | 17 ft (5.2 m) | 25 ft (7.6 m) | 24 ft (7.3 m) | 20 ft (6.1 m) | 30 ft (9.1 m) | 23 ft (7.0 m) | 20 ft (6.1 m) | 30 ft (9.1 m) |
| Nozzle Jet Type | Conical | Conical | Conical | Conical | Conical | Conical | Conical | Conical | Conical |
| Optional Features | |||||||||
| • Low temperature (down to -65°F / -54°C) | N/A | X | N/A | N/A | X | X | N/A | X | X |
| • Corrosion resistant | N/A | X | X | X | X | X | X | X | X |
| • Needle valve | X | X | X | X | X | X | X | X | X |
| • High flow rate | N/A | N/A | N/A | N/A | X | X | N/A | X | X |
| Optional Flow Rate | - | - | - | - | 1.55 lb/s (0.70 kg/s) | 1.55 lb/s (0.70 kg/s) | - | 2.10 lb/s (0.95 kg/s) | 2.35 lb/s (1.10 kg/s) |
| Optional Effective Discharge Time | - | - | - | - | 12 seconds | 12 seconds | - | 12 seconds | 12 seconds |
| Optional Effective Range | - | - | - | - | 15–20 ft (4.6–6.1 m) | 15–20 ft (4.6–6.1 m) | - | 15–20 ft (4.6–6.1 m) | 15–20 ft (4.6–6.1 m) |
| Optional Classification | - | - | - | - | 1-A:20-B:C | 20-B:C | - | 1-A:20-B:C | 20-B:C |
| Certifications | UL, FM, USCG** | UL, FM, USCG** | UL, FM, USCG** | UL, FM, USCG** | UL, FM, USCG** | UL, FM, USCG** | UL, FM, USCG** | UL, FM, USCG** | UL, FM, USCG** |
| Mounting Brackets | |||||||||
| • Universal bracket*** | 14228 | 14228 | 14228 | 14091 | 14091 | 14091 | 14098 | 14098 | 14098 |
| • High resistance bracket*** | 30886 | 30886 | 30886 | 3075 | 30759 | 30759 | 30889 | 30889 | 30889 |
| • High resistance ring pass-through bracket | N/A | N/A | N/A | 15665 | 15665 | 15665 | 25428 | 25428 | 25428 |
| Full Charged Weight | 22 lb (10.0 kg) | 20.5 lb (9.3 kg) | 21 lb (9.5 kg) | 38 lb (17.2 kg) | 35 lb (15.9 kg) | 36 lb (16.3 kg) | 54.5 lb (24.7 kg) | 49.5 lb (22.5 kg) | 51.5 lb (23.4 kg) |
| Dimensions | |||||||||
| Height | 16.1" (40.9 cm) | 16.1" (40.9 cm) | 16.1" (40.9 cm) | 20.5" (52.1 cm) | 20.5" (52.1 cm) | 20.5" (52.1 cm) | 22.5" (57.2 cm) | 22.5" (57.2 cm) | 22.5" (57.2 cm) |
| Width | 8.3" (20.9 cm) | 8.3" (20.9 cm) | 8.3" (20.9 cm) | 10.4" (26.4 cm) | 10.4" (26.4 cm) | 10.4" (26.4 cm) | 11.1" (28.3 cm) | 11.1" (28.3 cm) | 11.1" (28.3 cm) |
| Depth | 5.3" (13.3 cm) | 5.3" (13.3 cm) | 5.3" (13.3 cm) | 7.0" (17.8 cm) | 7.0" (17.8 cm) | 7.0" (17.8 cm) | 8.0" (20.3 cm) | 8.0" (20.3 cm) | 8.0" (20.3 cm) |
| Hose Inner Diameter | 0.4" (0.9 cm) | 0.4" (0.9 cm) | 0.4" (0.9 cm) | 0.5" (3 cm) | 0.5" (1.3 cm) | 0.5" (1.3 cm) | 0.6" (1.6 cm) | 0.6" (1.6 cm) | 0.6" (1.6 cm) |
| Hose Length | 26.6" (67.6 cm) | 26.6" (67.6 cm) | 26.6" (67.6 cm) | 31.6" (80.3 cm) | 31.6" (80.3 cm) | 31.6" (80.3 cm) | 35.6" (90.5 cm) | 35.6" (90.5 cm) | 35.6" (90.5 cm) |
| Cylinder Outer Diameter | 4.9" (12.4 cm) | 4.9" (12.4 cm) | 4.9" (12.4 cm) | 6.0" (15 cm) | 6.0" (15 cm) | 6.0" (15 cm) | 7.0" (17.5 cm) | 7.0" (17.5 cm) | 7.0" (17.5 cm) |
| Fire Suppression Coverage* | |||||||||
| Novice Operator Coverage | 30 ft² (2.8 m²) | 40 ft² (3.7 m²) | 60 ft² (5.6 m²) | 40 ft² (3.7 m²) | 60 ft² (5.6 m²) | 80 ft² (7.4 m²) | 60 ft² (5.6 m²) | 80 ft² (7.4 m²) | 120 ft² (11.1 m²) |
| Experienced Operator Coverage | 75 ft² (6.9 m²) | 100 ft² (9.3 m²) | 150 ft² (13.9 m²) | 100 ft² (9.3 m²) | 150 ft² (13.9 m²) | 200 ft² (18.6 m²) | 150 ft² (13.9 m²) | 200 ft² (18.6 m²) | 300 ft² (27.9 m²) |
Working Mechanism
When the valve lever is pressed, the sealing interface is mechanically opened and nitrogen gas begins to expand inside the cylinder.
The process follows three controlled steps:
- nitrogen pressure acts on powder bed and pushes solid particles into dip tube inlet
- powder is transferred through internal channel and valve body under gas-driven flow
- nozzle converts pressure energy into directional particle stream toward combustion zone
During discharge, the system maintains continuous powder flow for a controlled time window under 195–240 PSI pressure decay behavior, depending on temperature and valve resistance.

Material & Component System
Cylinder body
material: carbon steel sheet with welded or seamless forming (configuration dependent)
function: resist internal gas pressure and maintain structural integrity under cyclic load
pressure test: hydrostatic verification typically above 3× working pressure level
Powder agent
composition: ABC dry chemical powder (ammonium phosphate based)
particle function: forms insulating layer on burning surface and blocks oxygen diffusion channels
storage condition: sealed internal environment to reduce moisture-induced agglomeration
Valve system
details: brass alloy valve body with manual lever structure
sealing: interface uses elastomer O-ring to reduce nitrogen leakage under static storage pressure
dip tube: rigid polymer or metal tube conducts powder from bottom reservoir
Each component is designed to transfer pressure energy into solid particle motion without phase conversion.
Fire Application Conditions
The 20 LBS configuration is selected for medium fire load density zones where localized suppression is required within 10–12 m distance range.
Class A solid combustion zones
Materials: stacked wood pallets, cardboard cartons, textile storage
Condition: surface combustion with oxygen diffusion
Action: powder deposits on surface and interrupts oxidation reaction pathway
Class B liquid fuel zones
Materials: gasoline, diesel, industrial lubricants
Condition: vapor combustion above liquid surface
Action: powder disperses flame layer and reduces vapor ignition continuity
Class C electrical zones
Condition: energized equipment (low to medium voltage industrial systems)
Requirement: non-conductive discharge behavior under gas-powder system
Action: powder separates flame path without electrical conduction
Pressure System Behavior
The extinguisher operates under nitrogen-driven pressure range of 195–240 PSI, which varies with ambient temperature between -30°C to +60°C operating window.
Key pressure behaviors:
- temperature drop: gas contraction reduces discharge range
- temperature rise: internal pressure increases and accelerates powder flow
- seal degradation: micro-leakage reduces stored energy capacity
The system uses hydrostatic validation and seal compression control to maintain pressure retention during storage and transport cycles.
Installation & Integration Method
The unit is installed as a mechanical fire response module in fixed positions:
- wall bracket mounting using steel support frame
- anchor bolts (M8 specification commonly used in industrial installation)
- installation height typically aligned with manual access zone (0.8–1.2 m range)
Operational integration:
- no electrical input required
- no pipeline connection required
- activation performed by manual lever displacement that opens valve sealing path
The system is designed to convert static storage pressure into immediate discharge response without auxiliary systems.
Failure Modes & Engineering Risk Control
Identified failure mechanisms:
- valve seal fatigue ➔ nitrogen leakage reduces internal pressure below operational threshold
- powder moisture absorption ➔ increases internal friction and blocks dip tube flow
- nozzle restriction ➔ reduces particle velocity and effective discharge distance
- cylinder corrosion ➔ localized wall thinning under long-term humidity exposure
Control methods applied in production:
- controlled humidity filling environment during powder loading
- torque-controlled valve assembly to maintain seal compression force
- batch sampling discharge test to verify flow continuity and pressure retention
Manufacturing & Quality Traceability
Weimin production process separates structural, filling, and pressure stages:
- cylinder forming and welding or seamless shaping
- hydrostatic pressure test to validate structural integrity
- internal surface treatment to reduce corrosion interaction
- ABC powder filling under controlled moisture conditions
- valve assembly with torque calibration
- nitrogen pressurization to 195–240 PSI target range
- final inspection including weight verification and batch traceability marking
Each unit is linked to a batch-level production record for export inspection tracking.
Procurement Interface
For configuration and quotation, buyers typically define:
- installation scenario: warehouse / commercial building / industrial system
- fire risk type: solid combustible / liquid fuel / electrical exposure
- compliance requirement: US market installation standard
- order quantity: project sample / container shipment level
Weimin responds with:
Pressure and cylinder configuration sheet • Export compliance documentation set • OEM label and marking structure • Production-based FOB quotation
Request for Quotation
Weimin will map cylinder pressure system, valve configuration, and powder specification into a production quotation package based on batch manufacturing capability.
Submit Your Inquiry to WeiminHot Tags: 20 lbs powder fire extinguisher(usa module), China 20 lbs powder fire extinguisher(usa module) manufacturers, suppliers, factory, 20 LBS ABC Fire Extinguisher, 20LBS Fire Extinguisher, 2KG ABC Fire Extinguisher, 2KG Dry Powder Fire Extinguisher, ABC 10LBS Fire Extinguisher, Dry Chemical Fire Extinguishers