Portable Aluminum CO2 Fire Extinguisher

Portable Aluminum CO2 Fire Extinguisher

Capacity Options: 5 lb, 10 lb, 15 lb, and 20 lb
Fire Rating: UL/ULC 5-B:C and 10-B:C ratings
Discharge Time: 9–20 seconds depending on model
Discharge Range: 4–8 ft (1.2–2.4 m)
Operating Temperature: -22°F to 120°F (-30°C to 49°C)
Mounting Type: Wall-mounted design
OEM Supply: Suitable for wholesale and project procurement, subject to customization availability.
Share to
Send Inquiry
Description
Technical Parameters

Shaoxing Weimin Fire Fighting Equipment Co., Ltd. is one of the most reliable manufacturers and suppliers of portable aluminum co2 fire extinguisher in China. If you're going to wholesale bulk CE and ISO approved portable aluminum co2 fire extinguisher, welcome to get pricelist and free sample from our factory. All customized products are with high quality and low price.

 

Lightweight Aluminum Cylinder Design for Clean and Efficient Fire Suppression

The Portable Aluminum CO2 Fire Extinguisher features an aluminum alloy cylinder that offers a lightweight alternative to conventional steel cylinders. Using carbon dioxide (CO2) as the extinguishing agent, it provides clean fire suppression without powder residue. It is suitable for specified electrical equipment and Class B fire risks.

Weimin Fire provides fire equipment supply, OEM customization, and export support for international distributors, wholesalers, and project buyers.

Custom Portable Aluminum CO2 Fire Extinguisher

Key Features of Portable Aluminum CO2 Fire Extinguisher

Lightweight Aluminum Cylinder and Clean CO2 Fire Suppression

Lightweight Aluminum Cylinder

Reduces cylinder weight compared with conventional steel designs for easier handling and transportation.

01

Clean CO2 Discharge

Leaves no dry chemical powder residue after discharge.

02

Electrical Fire Protection

Suitable for specified energized electrical equipment fire risks.

03

Portable Design

Convenient for placement and handling in commercial and industrial facilities.

04

OEM Customization

Supports customized branding, labels, and packaging according to order requirements.

05

Small CO2 Fire Extinguisher Technical Specifications

 

 

Product Parameters for Aluminum CO2 Fire Extinguisher Selection

The Portable Aluminum CO2 Fire Extinguisher is available in four capacity options: 5CD, 10CD, 15CD, and 20CD. Each model features different agent capacities, discharge times, dimensions, and approval classifications to meet various fire protection requirements.

Specifications 5CD 10CD 15CD 20CD
Part Number 45100 (45191) 45600 (45691) 46100 (46191) 46600 (46691)
Agent Capacity 5 lb (2.27 kg) 10 lb (4.54 kg) 15 lb (6.8 kg) 20 lb (9.07 kg)
UL/ULC Rating 5-B:C 10-B:C 10-B:C 10-B:C
Temperature Range -22°F to 120°F (-30°C to 49°C) -22°F to 120°F (-30°C to 49°C) -22°F to 120°F (-30°C to 49°C) -22°F to 120°F (-30°C to 49°C)
Discharge Time 9 sec 9 sec 15 sec 20 sec
Discharge Range 4–8 ft (1.2–2.4 m) 4–8 ft (1.2–2.4 m) 4–8 ft (1.2–2.4 m) 4–8 ft (1.2–2.4 m)
Mount Type Wall Wall Wall Wall
USCG Approval Classification Type B:C Size I Type B:C Size I Type B:C Size II Type B:C Size II
Shipping Weight 13.75 lb (6.3 kg) 27.75 lb (12.6 kg) 37.75 lb (17.1 kg) 49 lb (22.2 kg)
Unit Height 17.375 in (44.1 cm) 19.75 in (50.2 cm) 26.375 in (67 cm) 26.875 in (68.2 cm)
Unit Width 8.25 in (21 cm) 12 in (30.5 cm) 12 in (30.5 cm) 13 in (33 cm)
Unit Diameter 5.25 in (13.3 cm) 6.89 in (17.5 cm) 6.89 in (17.5 cm) 8 in (20.3 cm)

Note: Specifications are based on the supplied product data. Confirm the applicable part number and configuration when placing an order.

Small CO2 Fire Extinguisher Applications

Portable CO2 Fire Extinguisher Applications in Commercial and Industrial Facilities

large ecterprise scale

Protection for specified electrical equipment fire risks.

01

Server Rooms

Clean fire suppression for designated equipment areas.

02

Laboratories

Suitable for applicable Class B and electrical fire risks.

03

Commercial Buildings

Fire protection for approved commercial installations.

04

Industrial Facilities

Suitable for designated electrical equipment and flammable liquid fire risks.

05

 Application suitability depends on fire classification, product certification, and local fire safety regulations. CO2 extinguishers are not suitable for every fire type.

Aluminum CO2 Cylinder Inspection and Quality Documentation

Aluminum CO2 Cylinder Inspection and Quality Documentation

For bulk fire extinguisher procurement, cylinder safety and product consistency are essential.

Weimin Fire operates under an ISO 9001 quality management system and coordinates relevant quality checks, including:

Cylinder Inspection: Appearance and material verification.

Pressure Testing: Inspection against applicable pressure requirements.

Valve Inspection: Checking valve assemblies and connections.

Leakage Inspection: Verifying sealing performance.

Product Documentation: Providing applicable test records and certification documents.

Product-specific certificates and inspection records can be confirmed according to the selected model and destination market.

 

FAQ

Q1: What is the difference between aluminum and steel CO2 fire extinguishers?

The main difference is cylinder material and weight. Aluminum cylinders are generally lighter, while both types use CO2 as the extinguishing agent.

Q2: Can an aluminum CO2 fire extinguisher be used for electrical fires?

Yes. CO2 extinguishers are suitable for specified energized electrical equipment fire risks, subject to product certification and local regulations.

Q3: Does a CO2 fire extinguisher leave residue?

No. CO2 discharge does not leave dry chemical powder residue.

Q4: What capacities are available?

Available capacities depend on the manufacturer's product range. Confirm filling capacity, dimensions, and total weight before ordering.

Q5: Can Weimin Fire provide OEM customization?

Weimin Fire supports OEM branding, label customization, and packaging arrangements for applicable orders. Specific options should be confirmed for the selected model.

Q6: What documents should buyers request?

Buyers should check product specifications, cylinder test records, pressure test documentation, applicable certificates, and export compliance documents.

Q7: What should importers confirm before bulk ordering?

Confirm cylinder material, capacity, working pressure, test pressure, fire rating, certifications, packaging, MOQ, and delivery schedule.

 

 

Hot Tags: portable aluminum co2 fire extinguisher, China portable aluminum co2 fire extinguisher manufacturers, suppliers, factory

Send Inquiry
Send Inquiry